CATEGORIAS


  9616073421   9616073421  ventas@mgsistemas.com.mx Circunvalación Pichucalco 165, Col. Moctezuma
TC: $18.16
MXN

Switch eKit Core Empresarial C...


Switching capacity224 Gbit/s
Packet forwarding rate168 Mpps
GE RJ4548 (1G/100M/10M)
10G SFP+4 (10G/1G)
iStackUp to 9 switches of the same series in a stack
Number of power slots2
CertificationEMC certification Safety certification Manufacturing certification
Chassis materialMetal
Static power consumption [W]25.31
Dimensions without packaging (H x W x D) [mm(in.)]Basic dimensions (excluding the parts protruding from the body): 43.6 mm x 442.0 mm x 420.0 mm (1.72 in. x 17.40 in. x 16.54 in.) Maximum dimensions (the depth is the distance from ports on the front panel to the parts protruding from the rear panel): 43.6 mm x 442.0 mm x 446.0 mm (1.72 in. x 17.40 in. x 17.56 in.)
Dimensions with packaging (H x W x D) [mm(in.)]185.0 mm x 650.0 mm x 550.0 mm (7.28 in. x 25.59 in. x 21.65 in.)
Installation typeRack mounting,Desk mounting
Weight without packaging [kg(lb)]5.43 kg (11.97 lb)
Weight with packaging [kg(lb)]7.19 kg (15.85 lb)
Typical power consumption [W]39.10
Maximum power consumption [W]- 55.12 W (with two 80 W AC power modules) - 64.51 W (with two 180 W AC power modules) - 93.26 W (with two 1200 W DC power modules)
Number of fans modules2
Redundant power supply1+1 Power modules without fans and power modules with fans cannot be installed in the same chassis.
Long-term operating temperature [°C(°F)]-5°C to +50°C (23°F to 122°F) at an altitude of 0-1800 m (0-5905.44 ft.)
Long-term operating relative humidity [RH]5% RH to 95% RH, non-condensing
Power supply modePluggable power supply
Input voltage range [V]- AC input: 90 V AC to 290 V AC; 45–65 Hz - High-voltage DC input: 190 V DC to 290 V DC - DC input: -38.4 V DC to -72 V DC
Power supply surge protection [kV]- Configured with AC power modules: ±6 kV in differential mode and ±6 kV in common mode - Configured with DC power modules: ±2 kV in differential mode and ±4 kV in common mode
Types of fansBuilt-in
Heat dissipation modeAir cooling for heat dissipation, intelligent fan speed adjustment
Airflow directionAir intake from left, front, and right and air exhaust from rear